B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 439 -
10200 Lower limit 6 of tool offsets No.01
to to
10219 Lower limit 6 of tool offsets No.20
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters set the lower limits of the following offset values:
- T series, with tool geometry/wear offsets, tool noise radius and
wear offsets
10220 Upper limit 6 of tool offsets No.01
to to
10239 Upper limit 6 of tool offsets No.20
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters set the upper limits of the following offset values:
- T series, with tool geometry/wear offsets, tool noise radius and
wear offsets
10240 Lower limit 1 of a tool offset number range No.01
to to
10259 Lower limit 1 of a tool offset number range No.20
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to maximum number of offset sets
Each of these parameters sets the lower limit of a tool offset number
range.
These parameters correspond to the tool offset lower/upper limits set