4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 444 -
#7 #6 #5 #4 #3 #2 #1 #0
10330 ASD EBC MID HSC ADC PDC IIC
[Input type] Parameter input
[Data type] Bit
# 0 IIC At the time of incremental input, a confirmation message is:
0: Displayed.
1: Not displayed.
# 1 PDC At the time of program deletion, a confirmation message is:
0: Displayed.
1: Not displayed.
# 2 ADC At the time of deletion of all data, a confirmation message is:
0: Displayed.
1: Not displayed.
# 3 HSC When a cycle start is executed halfway in the program, a confirmation
message is:
0: Displayed.
1: Not displayed.
# 4 MID Updated modal information is:
0: Highlighted.
1: Not highlighted.
# 5 EBC Program sum checking is:
0: Disabled.
1: Enabled.
# 6 ASD Axis state display is:
0: Enabled.
1: Disabled.
10331 Lower limit of external workpiece zero point offsets
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets the lower limit of external workpiece zero point
offsets.