B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 451 -
11905
Execution time percentage (%) of PMC of execution order 1 in the multi-PMC
function
11906
Execution time percentage (%) of PMC of execution order 2 in the multi-PMC
function
11907
Execution time percentage (%) of PMC of execution order 3 in the multi-PMC
function
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
Each of these parameters sets the execution time percentage (%) of
each PMC when the multi-PMC function is used.
When 0 is set in all of these parameters, the following initially set
execution time percentage values are used:
Initial setting of execution time percentages in the multi-PMC function
Multi-PMC configuration
PMC of
execution
order 1
PMC of
execution
order 2
PMC of
execution
order 3
First PMC only 100%
First PMC + second PMC 85% 15%
First PMC + third PMC 85% 15%
First PMC + second PMC + third
PMC
75% 15% 10%
NOTE
1 If a too small value is specified in these
parameters, the first level may not be started for
each scan.
2 Even if you input the same program in both second
and third PMC, the scan time of both programs
may not correspond because of changing of the
waiting time by execution timing.
3 If the sum of the values set in these parameters
exceeds 100, PMC alarm ERxx is issued, and none
of the PMCs can be started.