4.DESCRIPTION OF PARAMETERS B-63950EN/02
- 452 -
11910 I/O Link channel 1 input/output addresses
11911 I/O Link channel 2 input/output addresses
11912 I/O Link channel 3 input/output addresses
11913 I/O Link channel 4 input/output addresses
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 0, 100 to 103, 200 to 203, 300 to 303, 900
Each of these parameters sets I/O Link input/output addresses.
Input/output addresses of I/O Link channels
Setting value Input/output address
0 Initial setting (see below)
100 X0 to 127/Y0 to 127 of the first PMC
101 X200to327 / Y200to327 of the first PMC
102 X400to527 / Y400to527 of the first PMC
103 X600to727 / Y600to727 of the first PMC
200 X0to127 / Y0to127 of the second PMC
201 X200to327 / Y200to327 of the second PMC
202 X400to527 / Y400to527 of the second PMC
203 X600to727 / Y600to727 of the second PMC
300 X0to127 / Y0to127 of the third PMC
301 X200to327 / Y200to327 of the third PMC
302 X400to527 / Y400to527 of the third PMC
303 X600to727 / Y600to727 of the third PMC
900 X0 to 127/Y0 to 127 of the dual check safety PMC
When all of these parameters are set to 0, all channels are assigned to
the first PMC according to the initial setting as shown below.
First PMC
X/Y 0 to 127
X/Y 200 to 327
X/Y 400 to 527
X/Y 600 to 727
Channel 1
Channel 2
Channel 3
Channel 4
Initial input/output address setting for each I/O Link channel