B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 453 -
CAUTION
1 If a duplicate number is set when a value other than
0 is set in any of these parameters, PMC alarm
“ER52 I/O LINK CHANNEL ASSIGNMENT ERROR”
is issued, and none of the PMCs can be started.
2 If a parameter is not set, the assignment of PMC
addresses to the channel is disabled.
11920 Input/output addresses of NC-PMC interface 1
11921 Input/output addresses of NC-PMC interface 2
11922 Input/output addresses of NC-PMC interface 3
11923 Input/output addresses of NC-PMC interface 4
11924 Input/output addresses of NC-PMC interface 5
11925 Input/output addresses of NC-PMC interface 6
11926 Input/output addresses of NC-PMC interface 7
11927 Input/output addresses of NC-PMC interface 8
11928 Input/output addresses of NC-PMC interface 9
11929 Input/output addresses of NC-PMC interface 10
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 0, 100 to 109, 200 to 209, 300 to 309
Each of these parameters assigns PMC F/G addresses to CNC F/G
addresses.