B-63950EN/02 4.DESCRIPTION OF PARAMETERS
- 41 -
1: Valid
# 6 MCCx If a multi-axis amplifier is used, and another axis of the same
amplifier is placed in the control axis detach state, the MCC signal of
the servo amplifier is:
0: Turned off.
1: Not turned off.
NOTE
1 This parameter can be set for a control axis.
2 If the servo motor of an axis subject to control axis
detachment is connected to a multi-axis amplifier
such as 2-axis amplifier, and one axis is placed in
the control axis detach state, servo alarm (SV0401)
(V ready off) is issued on another axis. This alarm
can be prevented by setting this parameter.
# 7 RMBx The control axis detachment signal for each axis and the setting input
RMV (bit 7 of parameter No. 0012) are:
0: Invalid
1: Valid
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx DIAx ROSx ROTx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
ROTx, ROSx Setting linear or rotation axis.
ROSx ROTx Meaning
0 0
Linear axis
(1) Inch/metric conversion is done.
(2) All coordinate values are linear axis type. (Is not rounded in 0 to 360°)
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
0 1
Rotation axis (A type)
(1) Inch/metric conversion is not done.
(2) Machine coordinate values are rounded in 0 to 360_. Absolute coordinate values are rounded or not
rounded by parameter No.1008#0(ROAx) and #2(RRLx).
(3) Stored pitch error compensation is the rotation type. (Refer to parameter No.3624)
(4) Automatic reference position return (G28, G30) is done in the reference position return direction and the
move amount does not exceed one rotation.
1 1
Rotation axis (B type)
(1) Inch/metric conversion, absolute coordinate values and relative coordinate values are not done.
(2) Machine coordinate values, absolute coordinate values and relative coordinate values are linear axis
type. (Is not rounded in 0 to 360°).
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
(4) Cannot be used with the rotation axis roll over function and the index table indexing function (M series)
Except for the above. Setting is invalid (unused)
# 3 DIAx The move command for each axis is based on:
0: Radius specification