B-63950EN/02-03
Title
Draw
No.
Ed. Date Design Description
Date Design. Apprv.
3/3
page
FANUC Series 30i/300i/300is-MODEL A
FANUC Series 31i/310i/310is-MODEL A5
FANUC Series 31i/310i/310is-MODEL A
FANUC Series 32i/320i/320is-MODEL A
The correction of PARAMETER MANUAL
#7 #6 #5 #4 #3 #2 #1 #0
8103 MWP MWT
[Input type] Parameter input
[Data type] Bit
NOTE
When this parameter is set, the power must be turned off before
operation is continued.
# 0 MWT As the signal interface for the waiting M code:
0: The path individual signal interface is used.
1: The path common signal interface is used.
This parameter can be selected only when 2-path control is used.
# 1 MWP To specify a P command for the waiting M code/balance cut:
0: A binary value is used as conventionally done.
1: A path number combination is used.
(2)
(2)