Series 30i/ 31i/ 32i-MODEL A
Supplemental PMC Programming Manual
01 04.06.30
T. Matsukawa
New registration
B-63983EN/02-1
EDIT
DATE
DESIG.
DESCRIPTION
44/56
DRAW.NO.
7.1.3 NET EDITOR Screen
At NET EDITOR screen, you can create new net, and modify existing
net.
Replace the following after”8.3.3 NET EDITOR screen Changing existing nets”
• Changing existing nets
If you move a net with the [ZOOM] soft key, you will enter a mode
(Modify mode) in which you can change the net.
You can select the net to be modified, either a net under the cursor or
multiple nets near the cursor by setting of "ZOOM MODE" on ladder
diagram editor setting screen.
• Adding a new net
When [CREATE NET] soft key is used, this screen is in "New mode"
to create new net from nothing.
Following operations are available at this screen:
• Place new contacts and coils "bit address" + [
], [ ],
etc.
• Change type of contacts and coils [
], [ ], etc.
• Place new functional instructions [FUNC]
• Change type of functional instructions [FUNC]
• Erase contacts, coils, and functional instructions [
]
• Draw/erase connecting lines [
], [ ], [ ]
• Edit data table of functional instructions [DATA TABLE]
• Insert line/column [INSERT LINE], [INSERT COLUMN],
[APPEND COLUMN]
• Change address of contacts and coils "bit address" + INPUT key
• Change parameters of functional instructions "number" or "byte
address" + INPUT key
• Abandon modifications [CANCEL EDIT]
• Restore the net to the state it was before editing [RESTRE]