3 ADDITIONAL SPECIFICATION OF
WINDOW INSTRUCTIONS
The following functions has been added to the Window functions.
(1) Reading/Writing a "null" state that means the value is not defined,
have been added to the following Function codes.
Function code Description
21 Reading a Custom Macro variable
22 Writing a Custoom Macro variable
59 Reading a P-CODE Macro variable
60 Writing a P-CODE Macro variable
(2) Reading a group No.21 to 33 of G-code has been added to the
following Function code.
Function code Description
32 Reading modal data
Add following iteams to the "1. Compatibility with Series16i/18i/21i" in the "5 WINDOW FUNCTION"
• The function "No.21 Reading a custom macro variable" or
"No.59 Reading a P-CODE macro variable" returns
"mantissa"=0 and "number of decimal places"= -1 when
the floating-point type variable is "null".
• The function "No.22 Writing a custom macro variable" or
"No.60 Writing a P-CODE macro variable" can write
"null" to the floating-point type variable by setting
"mantissa"=0 and "number of decimal places"= -1.
• The function "No.32 Reading modal data" cannot read a
modal information for a block after the next block.