5.WINDOW FUNCTIONS B-63983EN/02
- 462 -
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
32
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 2, 6, 2*n, 6*m)
(Data number)
N
(N: Input data)
(Data attribute)
M
(M: Input data)
Modal data for G function (2 bytes)
See the data format for the G
function. The upper byte must always
be set to 0.
Value
8
10
(Data attribute)
M
(M: Input data)
Data part of modal data for other than
G function (4 bytes)
See the data format for other than the
G function.
Value
14
Flag part of modal data for other than
G function (2 bytes)
See the flag format of the data for
other than the G function. The upper
byte must always be set to 0.
Or
L = 2 : G function
L = 2*n : All data for G function
L = 6 : Other than G function
L = 6*m : All data for other than G function
(n: Number of groups for the G
function)
(m: Number of types other than for the
G function)
When all data items are specified to be read, the data items are all
output simultaneously in the order specified in the above data table.