5.WINDOW FUNCTIONS B-63983EN/02
- 612 -
Top address + 86
+90
+94
+150
»»
Customized data 4 (4 bytes)
Customized data 5 (4 bytes)
Customized data 6 (4 bytes)
»
»
Customized data 20 (4 bytes)
»
»
+230
Customized data 40 (4 bytes)
Customized data 21 (4 bytes)
+154
[Completion codes]
0: The processing has been executed normally.
2: The data length is invalid.
3: The specified cartridge number or pot number is invalid.
5: The input data is invalid.
6: The necessary option is not found.
7: The area is protected.
9: Free pot.
[Detailed completion codes]
The detailed completion code is always 0 when the completion code is
other than 3 or 5.
When the completion code is 3, the detailed completion code is one of
the following values:
21: The cartridge number is invalid.
22: The pot number is invalid.
When the completion code is 5, the detailed completion code is one of
the following values:
1: The specified tool type number is invalid.
2: The specified tool life counter is invalid.
3: The specified maximum tool life value is invalid.
4: The specified predicted tool life value is invalid.
5: The specified tool life status is invalid.
7: The specified tool information is invalid.
8: The specified tool length compensation number (H) is invalid
[for the machining and lathe systems (compound)].