7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 672 -
7.3 SETTING AND DISPLAYING PMC PARAMETERS
PMC parameters (timer, counter, keep relay, and data table) can be set
and displayed on each screen. Moreover, data items can be input
successively. The cursor moves to the last data item successively
input.
Method of input
(1) As the data delimiter, ";" (EOB) is used.
Example: "100;200;300;" + Input key
(2) With ;=, the value of the immediately preceding data item is
input.
Example: "100;=;=;200;=" + Input key inputs 100,100,100,200,
200.
(3) With ;;, data items can be input, skipping an address.
Example: "100;;100" + Input key inputs no data for the second
item.
(4) With "R;input-value;count", the same value can be input as many
times as a specified count.
Example: "R;100;200" + Input key inputs two hundred 100s in a
column.