8.LADDER DIAGRAM MONITOR AND EDITOR SCREENS ([PMC LADDER]) B-63983EN/02
- 838 -
(5) [BYTE] Change to the BYTE length
Changes data length to 1 byte. If overflowed data is found, the
cursor points it, and this operation aborts. Then, correct it and
press [BYTE] soft key again.
(6) [WORD] Change to the 2 BYTE length
Changes data length to 2 bytes. If overflowed data is found, the
cursor points it, and this operation aborts. Then, correct it and
press [WORD] soft key again.
(7) [DWORD] Change to the 4 BYTE length
Changes data length to 4 bytes.
NOTE
On functional instruction CODB, the data type is
decided by the first parameter of it. So, if you change
data type, the first parameter is changed too.
When you added functional instruction CODB to
ladder program, the default data type is BYTE.
(8) [COUNT] Change the number of data
Changes the number of data. If you expanded the number of data,
"0" is set to expanded data as default.
NOTE
In case of functional instruction COD, the number of
data is decided by the first parameter of it. In case of
functional instruction CODB, the number of data is
decided by the second parameter of it. If you change
the number of data, these parameters are changed
too.
(9) [INIT] Initialize all of data
Initializes all of data to "0". The number of data is not changed.
(10) [EXIT] Exit Editor
Ends the FUNCTIONAL INSTRUCTION DATA TABLE
EDITOR screen and switches to NET EDITOR screen.
(11) Cursor move keys, page change keys
You can move the cursor by all cursor move keys and page
change keys.
(12) Operation of the return key
On the FUNCTIONAL INSTRUCTION DATA TABLE
EDITOR screen, the return key has no effect.
After you have finished editing ladder net data, and want to
return to the LADDER DIAGRAM EDITOR screen, use the
[EXIT] soft key.