B–63505EN/02
1. DISPLAY AND OPERATION
85
The parameters necessary for the functions of the slave must be specified
in advance.
1. Press the [SYSTEM] function selection soft key. The following soft
keys appear.
[ PARAM ][ DGNOS ][ ][SYSTEM][ ]
2. Press the [PARAM] soft key. The parameter screen appears.
POWER MATE CNC MANAGER
PARAMETER
1.GROUP0 / β
0000 00001000 0010 11110000
0001 00010101 0011 01010000
0002 11111011 0012 00000000
0003 00000000 0013 00000000
0004 00000000 0014 10110001
0005 10100001 0015 00000000
0006 00000000 0016 00000000
0007 10000000 0017 10000010
0008 00000000 0018 00000000
0009 00000000 0019 00000000
[ PARAM ][ DGNOS ][ ][ SYSTEM ][ ]
The screen displays just the bit and decimal data. For details of the
parameters, refer to the connection manual of the corresponding Power
Mate.
D Searching for a parameter
A search can be made for the parameter to be displayed.
1. Select the active slave.
2. Press the [(OPRT)] soft key. The following soft keys appear.
[ NO.SRC ][ ][ ][ ][ INPUT ]
3. Enter a desired number in the key–in field by using MDI numeric keys.
Then, press the [NO.SRC] soft key. The search starts.
D Setting a parameter
A parameter of a slave Power Mate can be directly set from the CNC.
1. Select the active slave.
2. Press the [(OPRT)] soft key. The following soft keys appear:
[ NO.SRC ][ ][ ][ ][ INPUT ]
3. Move the cursor to the parameter to be set.
4. Enter desired data in the key–in buffer by using MDI numeric keys.
Then, press the [INPUT] soft key. Alternatively, press the MDI
INPUT
key.
D Parameter screen