2. HARDWARE
B–63505EN/02
112
4. Replace the batteries in the case.
Take care to place the batteries facing in the correct direction. (Insert
the batteries as shown in the diagram with 2 facing one way and 2 the
other.)
Thread
Lid
5. Having exchanged the batteries put the lid back on.
6. Procedure completes.
In case that the α series servo drive is used, the battery for absolute pulse
coder could be provided on the α series servo amplifier module instead
of the battery case as shown in 1.3. In this case the battery is not an
alkaline battery but a lithium battery, A06B–6073–K001. Prepare the
battery in advance and replace it by the following procedure.
Observe the following precautions for lithium batteries:
WARNING
If an unspecified battery is used, it may explode.
Replace the battery only with the specified battery
(A06B–6037–K001).
Dispose of used lithium batteries as follows:
(1) Small quantities
Discharge the batteries and dispose of them as ordinary
nonflammablegarbage.
(2) Large quantities
Consult FANUC.
2.6.3
Replacing Batteries for
Absolute Pulse Coder
(α Series Servo
Amplifier Module)