2. HARDWARE
B–63505EN/02
118
The peripheral units, such as the control unit and CRT/MDI, have been
designed on the assumption that they are housed in closed cabinets. In this
manual “cabinet” refers to the following:
(1)Cabinet manufactured by the machine tool builder for housing the
control unit or peripheral units;
(2)Cabinet for housing the flexible turnkey system provided by FANUC:
(3)Operation pendant, manufactured by the machine tool builder, for
housing the CRT/MDI unit or operator’s panel ;
(4)Equivalent to the above.
The environmental conditions when installing these cabinets shall
conform to the following table.
Room temperature
of unit
In operation 0°C to 55°C
In storage or transportation –20°C to 60°C
Change in temper-
ature
1.1°C/minute max.
Relative
humidity
Normal : 75% or less
Temporary (with 1 month) : 95% or less
Vibration In operation : 0.5 G or less
Environment Normal machine shop environment
(The environment must be considered if the cabinets
are in a location where the density of dust, coolant, and/
or organic solvent is relatively high.)
The following units related to the CNC control unit require input power
of 24 VDC ± 10% :
Table 2.10 Power supply
Unit
Power supply
voltage
Power supply
Control unit 24 VDC ± 10% 3.4A (only control unit)
Control unit
(± 10% includes
momentary
3.5A (only control unit)
When HSSB is used.
9″ CRT unit
surges and
ripples.)
0.8A
8.4″ TFT color LCD unit
ripples.)
0.8A
7.2″ STN monochrome LCD unit 0.8A
10.4″ TFT color LCD unit 0.8A
2.9
ENVIRONMENTAL
REQUIREMENT
2.10
POWER SUPPLY