3. INPUT AND OUTPUT OF DATA
B–63505EN/02
126
6. After the parameters have been input, set PARAMETER WRITE on
the SETTING screen to 0. Press
RESET
to release alram 100.
7. Convenient method
1) To change parameters in bit unit, press cursor key
or ,
then the cursor becomes bit length and you can set parameters bit
by bit (Bit parameter only).
2) To set data consecutively, use
EOB
key.
(Ex.1)
1 2 3 4 EOB 4 5 6 7 EOB 9
9 9 9 INPUT
This key sequence sets data as follows:
0 1234
0
4567
0
⇒
9999
0 0
(Ex.2)
1 2 3 4 EOB EOB 9 9 9 9 INPUT
This key sequence sets data as follows:
0 1234
0
0
0
⇒
9999
0 0
3) To set the same data sequentially, press
= .
(Ex.)
1 2 3 4 EOB = EOB = INPUT
This key sequence sets data as follows:
0 1234
0
1234
0
⇒
1234
0 0
4) Bit parameters can be set as follows:
(Ex.)
1 1 EOB = EOB = INPUT
This key sequence sets data as follows:
000
0 0000 00011000
00000000
00011000
00000000
⇒
000
1 1000
00000000 00000000
8. After the required parameters are set, set PARAMETER WRITE to
0.