B–63505EN/02
3. INPUT AND OUTPUT OF DATA
127
The main CPU memorized the following data.
Outputting the data 1/O device while the CNC is rurnning normally
(1)CNC paramter
(2)PMC parameter
(3)Pitch error compensation amount
(4)Custom macro variable values
(5)Tool compensation amount
(6)Part program (machining program, custom macro program)
Be sure that data output cannot be done in an alarm status.
Parameters required for output are as follows :
(When changing a parameter, do so in MDI mode or in the emergency stop
state.)
#7
0000
#6 #5 #4 #3 #2 #1
ISO
#0
#1 (ISO) 0 : Output with EIA code
1 : Output with ISO code (FANUC cassette)
0020 Selection of I/O channel
0 : Channel 1 (I/O printed circuit board JD5A)
1 : Channel 1 (I/O printed circuit board JD5A)
2 : Channel 2 (I/O printed circuit board JD5B)
* In the example shown here, an I/O unit is connected to JD5A for data
input and output (I/O channel = 0).
#7
NFD0101
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
#0 (SB2) 0 : No. of stop bits is 1.
l 1 : No. of stop bits is 2.
#3 (ASI)l 0 : EIA or ISO code is used for input/output data.
1 : ASCII code is used.
#7 (NFD) 0 : Feed is output when data is output.
1 : Feed is not output when data is output.
3.2
INPUTTING/
OUTPUTTING
DATA
3.2.1
Confirming the
Parameters Required for
Data Output