B–63505EN/02
3. INPUT AND OUTPUT OF DATA
131
1. Set to the emergency stop state.
2. Confirm that the patameters required to input data is correct.
1) Press
OFFSET
SETTING
key several times, and press [SETING] to display
SETTING screen.
2) Confirm that PARAMETER WRITE=1.
3) Press
SYSTEM
key to select the parameter screen.
4)
0020 Selectionof I/O channel
l 0 : Channel 1 (I/O printed circuit board JD5A)
1 : Channel 1 (I/O printed circuit board JD5A)
2 : Channel 2 (I/O printed circuit board JD5B)
5)
#7
NFD0101
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
#0 (SB2) 0 : No. of stop bits is 1.
l 1 : No. of stop bits is 2.
#3 (ASI) 0 : EIA or ISO code is used.
1 : ASCII code is used.
#7 (NFD) 0 : Feed is output when punching out.
1 : Feed is not output when punching out.
6)
0102 Specification number of I/O device
0 RS–232–C (when another device than following device is used.)
1 FANUC Bubble cassette B1/B2
2 FANUCFloppy cassette F1
3 PROGRAM FILE Mate, FANUC FA Card adapter, FANUC
Floppy casette adapter, FSP–H
4 Not used
5 Portable tape reader
6 FANUC PPR, FSP–G, FSP–H
3.2.8
Inputting CNC
Parameters