B–63505EN/02
3. INPUT AND OUTPUT OF DATA
133
1. Release the emergency stop and select EDIT mode.
2. Confirm that PARAMETER WRITE=1 on the setting screen.
3. Press
PROG
key and soft key [PRGRM] to display program contents.
4. Press soft key [(OPRT)],
, [F SRH], and
3
[EXEC] to select
the pitch error compensation file.
5. Press
SYSTEM
key several times, soft key [PARAM], and
[PITCH] to select the screen for pitch error compensation amount.
6. Press soft key [(OPRT)] and
key.
7. Press soft key [READ] and [EXEC], then the pitch error
compensation amount is started to be input.
8. After data has been input, press
OFFSET
SETTING
key twice to display the
SETTING screen and return the PARAMETER WRITE to 0.
If the system is equipped with the custom macro fucntion, input the
variable values.
For PPR, item 4 is not required.
1. Confirm that EDIT mode is selected.
2. Turn off the program protect key (KEY2=1).
3. Press
PROG
key then soft key [PRGRM] to display program contents.
4. Press soft key [(OPRT)],
, [F SRH], and
4
[EXEC] to select
a file.
5. Press soft key [(OPRT)] and key
.
6. Press address
O
, a program number (0001 for example), soft key
[READ] and [EXEC] key, then custom macro variable values are
started to be input.
Input a program number that is not used.
7. Select MEMORY mode on the machine operator’s panel and press
cycle start button.
When the program is executed, macro variables are set.
8. Press
OFFSET
SETTING
key, key and soft key [MACRO] to select the custom
macro variable screen.
9. Press
5 0 0
and soft key [NO SRH] to display variable
number 500 and confirm the custom macro variables are set correctly.
Of the data displayed, 0 and vacant differ in meaning.
Vacant is an undefined variable. To set vacant, press soft key
[INPUT].
10.Select EDIT mode again.
11. Press
PROG
key to select the program display screen.
12.Press address
O
and a program number (0001 for example) ,then
press
DELETE
to delete the program.
3.2.10
Inputting Pitch Error
Compensation Amount
3.2.11
Inputting Custom Macro
Variable Values