4. INTERFACE BETWEEN NC AND PMC
B–63505EN/02
152
Char-
acter
Kinds Byte Addresses Remarks
Input signal from
X0 to X127 FANUC I/O Link
X
the machine to the
PMC (MT to PMC)
142
X1000 to X1011 Built–in I/O card *1)
Output signal from
Y0 to Y127 FANUC I/O Link
Y
the PMC to the ma-
chine (PMC to MT)
142
Y1000 to Y1005 Built–in I/O card *1)
F
Input signal from
the NC to the PMC
(NC to PMC)
256 F0 to F255
G
Output signal from
the PMC to NC
(PMC to NC)
256 G0 to G255
R0 to R999
1100
R9000 to R9099
Operation results,
reserved system area
R Internal relay
R0 to R999
1118
R9000 to R9117
Operation results,
reserved system deta
A
Message request
signal
25 A0 to A24
C Counter
80 C0 to C79
K0 to K16
K Keep relay
20
K7 to K19
Reserved system area
D Data table
1860 D0 to D1859
T Variable timer
80 T0 to T79
*1 Addresses X and Y for direct signals cannot be changed.
Function Contents
Display of sequence pro-
gram
Dynamic display of ladder diagram
Diagnostic function STitle data display
S signal status (symbol can be displayed)
S PMC alarm display
S Signal trace
S Memory contents display
S Signal waveform display (*)
S I/O connection status display (*)
Setting and displaying data S Timer
S Counter
S Keep relay
S Data table
Sequence program edit
function
Ladder diagram editing a ladder edit module is
required)
* Applicabe CNC is limited
4.2.2
Address
4.2.3
Built–in Debug
Function