4. INTERFACE BETWEEN NC AND PMC
B–63505EN/02
156
Press soft key [PMCLAD], and a sequence program is displayed
dynamically and operation monitoring can be confirmed :
LADDER NET 0001–0004
LOG1
TOP
BOTTOM SRCH
Number of net displayed
Comment
MONIT RUN
LOG1
LOG1
X008.4 *ESP
PORD POR
END1
ALWAYS1
EMERGENCY
POWER ON
STOP
RESET
W–SRCH N–SRCH
Ladder display
F–SCRH ADRESS
Other soft keys
SYMBOL
Switched each
time pressed
RUN/STOP status
1. Green (Low brightness) display Contacts :open Relay :off
2. White (High brightness) display Contacts : closed Relay : on
1. Use the cursor keys
or the page keys
PAGE
PAGE
to change
display positions.
2. [TOP]:Searches top of ladder.
3. [BOTTOM]:Search bottom of ladder.
4. Address.bit,[SRCH] or Signal name, [SRCH]
5. Address.bit,[W–SRCH] or Signal name ,[W–SRCH]
6. Net no.[N–SRCH]:Ladder is displayed from the specified net.
7. Functional instruction no. [F–SRCH] or Functional instruction
name[F–SRCH]
8. [ADRESS]:Signal is displayed by address and bit no.
9. [SYMBOL]:Signal is displayed by signal name (symbol).
(If symbol is not registered at program preparation time, the address
of the signal is displayed).
4.3.2
PMCLAD Screen
D Contents displayed
D Search method