B–63505EN/02
4.INTERFACE BETWEEN NC AND PMC
165
Change of signals is displayed as the same display as that on the
oscilloscope.
1 Parameter setting screen (1st page)
SCOPE
DELETE
MONIT RUN
SAMPLING TIME : 10 (1–10 SEC)
TRIGGER ADDRESS : G 0007.2
CONDITION : 0
(0: START 1: TRIGGER–ON 2: TRIGGER–OFF)
TRIGGER MODE : 0
(0: AFTER 1: ABOUT 2: BEFORE 3: ONLY)
INIT ADDRESS
(a)
(b)
(c)
(d)
PMC SIGNAL ANALYSIS(PARAM)
Select each item by
cursor key
(a) Set a sampling time.
(b)Specifies an address from which recording of signals is started.
(c) Set a condition under which recording is initiated.
0 : Started by soft key [START]
1 : Started by rise of a trigger signal after you press the soft key
[START]
2 : Started by fall of a trigger signal after you press the soft key
[START]
(d)Set a trigger mode
0 : Record signal status after the trigger condition is satisfied
1 : Record signal status before and after the trigger condition is
satisfied.
2 : Record signal status before the trigger condition is satisfied.
3 : Record signal status when the trigger condition is satisfied.
(Display is same as trace memory).
D ANALYS screen
(Ladder editing card is
required)
PMC–SA3