4. INTERFACE BETWEEN NC AND PMC
B–63505EN/02
170
1 Nonvolatile memory control
#7
K016
#6 #5 #4 #3 #2 #1 #0
#6(MWRTF1): Writing status in nonvolatile memory
#7(MWRTF2): For checking the writing status in nonvolatile memory
2 PMC system parameter
The following keep relays are used by the system, therefore they
cannot be used in the sequence program.
#7
K017
#6 #5 #4 #3 #2 #1 #0
#0(LADMASK) 0 : Dynamic display of ladder is executed.
1 : Dynamic display of ladder is not executed.
#1(PRGRAM) 0 : Built–in programmer is not used.
1 : Built–in programmer is used.
#2(AUTORUN) 0 : A sequence program is executed automatically after the power is
turned on.
1 : A sequence program is executed by sequence program soft key.
#4(MEMINP) 0 : Data input cannot be done in memory contents display function.
1 : Data input can be done in memory contents display function.
#5(TRCSTAT) 0 : Signal tracing starts by soft key [EXEC] in signal trace function.
1 : Signal tracing starts automatically by power on in signal trace
function.
#6(ANASTAT) 0 : Pressing [EXEC] key initiates sampling by signal waveform display
function.
1 : Turning power to on initiates sampling by signal waveform display
function.
#7(DTBLDSP) 0 : The PMC parameter data table control screen is displayed.
1 : The PMC parameter data table control screen is not displayed.
#7
K018
#6 #5 #4 #3 #2 #1 #0
#7
K019
#6 #5 #4 #3 #2 #1 #0
* The system uses the unused data areas for the PMC management
software. The settings should not be changed. Usually, all bits are set
to 0.