B–63505EN/02
7.TROUBLESHOOTING
277
Digital servo parameters are abnormal.
(Digital servo parameters are set incorrectly.)
1 Confirm the setting value of the following parameters:
PRM 2020 : Motor format number
PRM 2022 : Motor rotation direction
PRM 2023 : Number of pulses of velocity feedbacks
PRM 2024 : Number of pulses of position feedback
PRM 1023 : Servo axis number
PRM 2084 : Flexible feed gear ratio
PRM 2085 : Flexible feed gear ratio
Confirm the details with diagnosis function of CNC side.
2 Change the setting of this parameter to 0.
PRM 2047 : Observer parameter
3 Perform initial setting of digital servo parameters.
Refer to setcion 5.1 “INITIAL SETTING SERVO PARAMETERS” .
This data indicates the cause of servo alarm No. 417, detected by the NC.
If the alarm is detected by the servo, the PRM bit (bit 4 of DGN No. 0203)
is set to 1.
#7
0280
#6
AXS
#5 #4
DIR
#3
PLS
#2
PLC
#1 #0
MOT
#0(MOT) : The motor type specified in parameter No. 2020 falls outside the
predetermined range.
#2(PLC) : The number of velocity feedback pulses per motor revolution, specified in
parameter No. 2023, is zero or less. The value is invalid.
#3(PLS) : The number of position feedback pulses per motor revolution, specified in
parameter No. 2024, is zero or less. The value is invalid.
#4(DIR) : The wrong direction of rotation for the motor is specified in parameter No.
2022 (the value is other than 111 or –111).
#6(AXS) : In parameter No. 1023 (servo axis number), a value that falls outside the
range of 1 to the number of controlled axes is specified. (For example, 4 is
specified instead of 3.) Alternatively, the values specified in the
parameter are not consecutive.
7.22
ALARM 417
(DIGITAL SERVO
SYSTEM IS
ABNORMAL)
D Causes