7. TROUBLESHOOTING
B–63505EN/02
286
SRAM parameter error
(1)Data stored in the SRAM is invalid.
If a parity alarm is repeatedly issued immediately after the power is
turned on, turn off the power, then perform a memory all clear
operation. (See Section 1.12, “LIST OF OPERATIONS.”)
(2)If a parity alarm cannot be reset by a memory all clear operation, the
SRAM is considered to be defective.
Replace the FROM and SRAM module or the memory and spindle
module according to the data indicated below.
SYSTEM ALARM D401–01
912 SRAM PARITY : (LOW)
EAX EBX ECX EDX ESI EDI EBP ESP
00000620 00930063 00000000 009C0340 00000010 009404E0 00000938 0000FFDC
SS DS ES FS GS TR LDTR EFLAGS VECT ERRC ERROR–ADDRESS
06D8 0050 0050 0068 0338 0678 0028 00003046 FFFF 0078:0000916B
STACK (PL0)
3646 0338 7CBA 0001 0958 FFF8 0063 0346 0000 0000 0338 0FF1 03E8 0000 0000 0000
0000 0000 0000 0000
NMIC 11100000 00000100 01010001 10110101 01001011 10001100
ADRS 003C0000 01000100
Check the address indicated here.
1) When an address from 003C0000 to
003FFFFF (hexadecimal) is indicated:
Replace the FROM and SRAM module.
2) When an address from 00380000 to
003BFFFF (hexadecimal) is indicated:
Replace the memory and spindle module.
If no address is indicated, first replace the FROM and SRAM module,
then replace the memory and spindle module. (After module
replacement, perform a memory all clear operation.)
(3)If a parity alarm is not reset after replacing the FROM and SRAM
module or the memory and spindle module, replace the main board.
(After replacing the main board, perform a memory all clear
operation.)
7.30
ALARM 912 AND 913
(SRAM PARITY
ERROR)
Causes and Remedies