APPENDIX
B–63505EN/02
A. ALARM LIST
321
Message Contents and solution
PARAMETER NOTHING There is no parameter of the functional instruction.
PLEASE COMPLETE NET The error net was found in LADDER.
(solution) After correcting the error net, please continue operating.
PLEASE KEY IN SUB NO. Please input the number of the functional instruction.
(solution) If you do not input the functional instruction, please push soft key “FUNC”
again.
PROGRAM MODULE NOTHING You tried to edit though there was neither RAM for debugging nor ROM for sequence
program.
RELAY COIL FORBIT There is an unnecessary relay or coil.
RELAY OR COIL NOTHING The relay or the coil does not suffice.
PLEASE CLEAR ALL It is impossible to recover the sequence program.
(solution) Please clear the all data.
SYMBOL DATA DUPLICATE The same symbol name is defined in other place.
COMMENT DATA OVERFLOW The comment data area was filled.
(solution) Please reduce the number of the commnet.
SYMBOL DATA OVERFLOW The symbol data area was filled.
(solution) Please reduce the number of the symbol.
VERTICAL LINE ILLEGAL There is an incorrect vertical line of the net.
MESSAGE DATA OVERFLOW The message data area was filled.
(solution) Please reduce the number of the message.
1ST LEVEL EXECUTE TIME
OVER
The 1st level of LADDER is too large to complete execution in time.
(solution) Please reduce the 1st level of LADDER.