B–63505EN/02
1. DISPLAY AND OPERATION
21
Series 0i stores the following software in FLASH–ROM.
(1) CNC control software
(2) Macro executer software
(3) Digital servo software
(4) PMC control software
In a Series 0i, software (1) above is first loaded into DRAM for execution
at power–up.
Blink
character
LOADING BASIC TO DRAM.
When the software is loaded in DRAM, data in FLASH–ROM is checked
and if trouble occurs, the System monitor screen is displayed. If the
System monitor screen is displayed, FLASH–ROM module or main
board may be faulty.
For details of the system monitor screen, see Appendix C, “Boot System.”
SYSTEM MONITOR MAIN MENU
1. SYSTEM DATA LOADING
2. SYSTEM DATA CHECK
3. SYSTEM DATA DELETE
4. SYSTEM DATA SAVE
5. SRAM DATA BACKUP
6. MEMORY CARD FILE DELETE
7. NENORY CARD FORMAT
9. END
***MESSAGE***
SELECT MENU AND HIT SELECT KEY
[SELECT] [ YES ] [ NO ] [ UP ] [ DOWN ]
1.2
SCREEN DISPLAYED
IMMEDIATELY AFTER
POWER IS TURNED ON
1.2.1
Loading of Software
Loading screen to DRAM
1.2.2
System Monitor Screen