B–63505EN/02
1. DISPLAY AND OPERATION
33
(3)Press the [OPEHIS] soft key, then press the [SG–SEL] soft key. The
operation history signal selection screen is displayed.
OP_HIS SIGNAL SELECT O1000 N02000
No. ADDRES SIGNAL No. ADDRES SIGNAL
01 X0000 00001000 11 G0000 00000001
02 X0004 10000000 12 G0004 00000011
03 X0008 00001100 13 G0008 00000111
04 X0009 00111000 14 G0003 00001111
05 X0012 00001111 15 G0043 01100000
06 Y0000 01000000 16 ********
07 Y0004 00110000 17 ********
08 Y0007 00011100 18 ********
09 Y0008 00011100 19 ********
10 Y0010 00011100 20 ********
>
EDIT **** *** * * * 00:00:00
[OPEHIS] [SG–SEL] [ ] [ ] [ (OPE) ]
(1)On the operation history signal selection screen, press the [(OPRT)]
soft key.
OP_HIS SIGNAL SELECT O1000 N02000
No. ADDRES SIGNAL No. ADDRES SIGNAL
01 G0004 00000010 11 ********
02 ******** 12 ********
03 ******** 13 ********
04 ******** 14 ********
05 ******** 15 ********
06 ******** 16 ********
07 ******** 17 ********
08 ******** 18 ********
09 ******** 19 ********
10 ******** 20 ********
>
EDIT **** *** *** *** 00:00:00
[ ALLDEL ][ DELETE ][ ON:1 ][ OFF:0 ][ ]
(2)Press the cursor key or to position the cursor to a desired
position.
(3)Key in a signal type (X, G, F, or Y) and an address, then press the
INPUT
key.
Example) G0004
INPUT
Signal address G0004 is set in the ADDRES column. The
corresponding position in the SIGNAL column is initialized to
000000000.
(4)Select the bit to be recorded.
To select all bits of the specified signal address, press the [ON:1] soft
key while the cursor is positioned to 00000000 .
1.6.3
Setting the Input Signal
or Output Signal to be
Recorded in the
Operation History