B–63505EN/02
1. DISPLAY AND OPERATION
37
fG135 f f f f f f f
fG255 f f f f f f f
to
#7 #6 #5 #4 #3 #2 #1 #0
PMC→MT
#7
fY000
#6
f
#5
f
#4
f
#3
f
#2
f
#1
f
#0
f
fY127 f f f f f f f
to
fY1000 f f f f f f f
fY1007 f f f f f f f
to
CNC→PMC
#7
fF000
#6
f
#5
f
#4
f
#3
f
#2
f
#1
f
#0
f
fF255 f f f f f f f
to
Recorded data can be output to an input/output unit connected via a
reader/punch interface. An output record can be input from the
input/output unit.
Set the input/output unit to be used in setting parameters No. 0020 and
0100 to 0135.
To output the data, set a code in the ISO bit of a setting parameter (bit 1
of parameter No. 0000).
(1)Select EDIT mode.
(2)Press the
SYSTEM
key, then select the operation history display screen.
(3)Press the soft keys [(OPRT)],
, [PUNCH], and [EXEC] in this
order.
The data output to the FANUC Floppy Cassette or FANUC FA Card is
stored under file name OPERATION HISTORY.
(1)Select EDIT mode.
(2)Press the
SYSTEM
key, then select the operation history display screen.
(3)Press the soft keys [(OPRT)], , [READ], and [EXEC] in this
order.
1. MDI/soft key
2. Signal
3. Alarm
1.6.4
Inputting and
Outputting the
Operation History Data
D Output
D Input
D Output data format