1. DISPLAY AND OPERATION
B–63505EN/02
38
4. For extension (date or time)
The header and recorded operation data are output, in this order. The
operation history data is divided into four parts by identifier words. Data
other than the identifier words depends on the type.
T0 : Header
T50 : MDI/soft key
T51 : Signal
T52 : Alarm
T53 : For extension (date or time)
T(identifier word)
1) Header
T 0 C O P E R A T I O N
H I S T O R Y ;
C: Data word
2) MDI/soft key
T 5 0 P 0 to 1 H * * ;
P0: Usually
P1: At power–on
H **: Key code (See the following table.)
3) Signal
0 to 2550 to 6T 5 1 P H * * ,N * * ;
New data Old data
P0: X0000 and above
P2: G0000 and above
P4: Y0000 and above
P6: F0000 and above
N***: DI/DO number
H **: Signal information data (hexadecimal)
4) Alarm
0 to 10T 5 2 P * *N * * ;
P0: P/S No. 100
P1: P/S No. 000
P2: P/S No. 101
P3: P/S No. 0001 to 254
P4: Overtravel alarm
P5: Overheat alarm
P6: Servo alarm
P7: System alarm
P8: APC alarm
P9: Spindle alarm
P10: P/S alarm No. 5000 to 5999
P15: External alarm
N****: Alarm number (for P/S alarm, system alarm, and external alarm only)