B–63505EN/02
1. DISPLAY AND OPERATION
55
(4) Auxiliary function status
FIN: The completion signal FIN for an auxiliary function is being
awaited.
***: Other status
(5) Emergency stop and reset status (displayed at the location of items
mentioned in (3) and (4))
––EMG–– : Emergency stop status
–RESET–: CNC reset status (The state in which the reset signal or
the MDI RESET key remains active.)
(6) Alarm status
ALM : An alarm condition has been detected.
BAT : The lithium battery voltage is low (the battery is to be
replaced).
Blank: Other status
(7) Clock display: Hour:minute:second
(8) Program editing/running status
Input: Data is being input.
Output: Data is being output.
SRCH: A data search is under way.
EDIT: Editing such as insertion or modification is under way.
LSK: Label skip enabled at data input (until valid information
is read).
MBL APC: Look–ahead control (Multiple blocks are read in
advance.) mode.
Blank: Editing is not under way.