B–63505EN/02
1. DISPLAY AND OPERATION
59
(1) Display start condition
100 : Draws a waveform for the stored data.
(2)Sampling period: Invalid
(3)Trigger: Invalid
(4)Data number: The table below lists the numbers of the data items for
which a waveform can be displayed (n = 1 to 4). Numbers for which
no data is stored cannot be specified.
Data
No.
Description Units
00 Does not display a waveform. –
0n Servo error (8 ms) for the n–th axis (positional deviation) Pulses
(detection units)
1n Pulse distribution for the n–th axis (move command) Pulses
(input increments)
2n Torque for the n–th axis (actual current) % (relative to maxi-
mum current)
5n Actual speed for the n–th axis min
–1
6n Command current for the n–th axis % (relative to maxi-
mum current)
7n Thermal simulation data for the n–th axis % (OVC alarm ratio)
(5)Data units: Weight of data when 1 is specified. The data units are
automatically specified for each data item and need not be set unless
the units must be changed for some reason.
[Valid data range] 1 to 1000
[Unit] 0.001
(6)Signal address: Invalid
D Waveform diagnosis
parameters (storage
type)