1. DISPLAY AND OPERATION
B–63505EN/02
60
1. Press soft key [W.GRPH], then graph of waveform diagnosis is
displayed.
WAVE DIAGNOSE (GRAPHIC)
CH1 CH2
1.0
0.5
0
– 0.
5
– 1.
0
1.0
0.5
0
– 0.
5
– 1.
0
[START] [TIME³] [²TIME] [H–DOBL] [H–HALF]
2. Press soft key [(OPRT)], then the following soft keys are displayed.
The following three sets of soft keys are displayed by the
key.
[START] [TIME³] [²TIME] [H–DOBL] [H–HALF]
[START] [CH–1°] [CH–1±] [V–DOBL] [V–HALF]
[START] [CH–2°] [CH–2±] [V–DOBL] [V–HALF]
1) [START ] : Starts Graphic data
2) [TIME→] : Shift the waveform of channel 1 and 2 rightward
3) [←TIME] : Shift the waveform of channel and 2 leftward
4) [H–DOBL] : Double the time scale of the waveform of channel 1
and 2
5) [H–HALF] : Half the time scale of the waveform of channel 1 and 2
6) [H–DOBL] : Double the height of waveform of channel 1 and 2
7) [V–HALF] : Half the height of waveform of channel 1 and 2
8) [CH–1↑] : Shift the zero point of channel 1 upward
9) [CH–1↓] : Shift the zero point of channel 1 downward
10) [CH–2↑] : Shift the zero point of channel 2 upward
11) [CH–2↓] : Shift the zero point of channel 2 downward
The one–shot type waveform diagnosis function draws a waveform for a
specified data item in real time as the data is sampled. The sampled data,
however, is not stored and thus cannot be output later.
To sample data for one–shot type waveform diagnosis, press the
[START] key on the WAVE DIAGNOS. (GRAPHIC) screen. Then, data
is sampled when the specified start condition is satisfied. Data sampling
continues for the specified period.
1.10.3
Graphic of Wave
Diagnosis data
D Drawing a waveform for
one–shot type waveform
diagnosis