1. DISPLAY AND OPERATION
B–63505EN/02
62
(1)Press the
SYSTEM
function key. Pressing the menu continuation key
displays the [W.DGNS] soft key. Press this soft key to display
the WAVE DIAGNOS. (PARAMETER) screen.
(2)Press the [W.MEM] soft key to display the WAVE DIAGNOS.
(MEMORY) screen. The operation selection soft keys appear.
The configuration of the operation selection soft keys is as follows:
WAVE DIAGNOS. (MEMORY) O1234 N12345
CONDITION: 100 TRIGGER: G0123.4
DATA KINDS SAMPLING AXIS
POS ERROR XYZA
MOTION CMD XYZA
CURRENT (%) XYZA
SPEED (RPM) NONE
TORQUE CMD NONE
HEAT SIMLT XYZA
SMPL TIME : 2. 0SEC
DATE : MEMORY
[SELECT] [ ] [ ] [ ] [START]
EDIT **** *** *** 08:20:52
(3)The configuration of the operation selection soft keys is as
follows:
Press
[W.PRM] [W.GRPH] [ W.MEM ] [ ] [ ]
[SELECT] [ ] [ ] [ ] [START]
[ ] [ ] [PUNCH] [ ] [ ]
Fig. 1.10.4 Soft keys
(4)Using the cursor, set the necessary data items. To set the sampling
axes, position the cursor to the data item to be set, enter the names of
the axes for which data will be sampled for that data item, then press
[SELECT] or
INPUT
. The axis names are displayed to the right of the
data items.
Example) XYZ + [SELECT] or
INPUT
(5)Once the sampling axes have been selected, the sampling period for
each axis is displayed. Subsequently pressing the [START] soft key
starts data sampling.
1.10.4
Data Sampling for
Storage Type
Waveform Diagnosis