1. DISPLAY AND OPERATION
B–63505EN/02
66
In the servo alarm format, the header, date and time, selected axes, and
waveform diagnosis data are output in this order. Data items are identified
by nine identifier words. Output data other than the identifier words
varies with the data type.
T0 : Header
T60 : Positional deviation
T61 : Move command
T62 : Actual current
T63 : Actual speed
T64 : Command current
T65 : Thermal simulation
T68 : Selected axes
T69 : Date and time
T(identifier word)
1) Header
T 0 C W A V E D I A G N O S ;
C: Data word
2) Data word
T 6 9 D * * * * * * , * * * * * * ;
T 6 9 D 1 9 9 7 0 6 2 3 , 1 2 1 4 5 9 ;
D *..*: Data Example: 12:14 59 seconds on June 23, 1997
3) Selected axes
T 6 8 P * * D * * , * * , to * * ,
P0: Positional deviation
P1: Actual speed
P2: Move command
P3: Command current
P4: Actual current
P5: Thermal simulation
D*.. *: Axis number (1 to 8)
D Output format