EDT
DATE
FANUC Series 16i/18i
Spindle Synchronous Control with
any spindle
A-63502E
8/11
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
4034
Shift amount in spindle phase synchronization
Data type : Word axis
Data unit : 1pulse(360deg./4096)
Data range : 0 to 4095
Specify shift amount from reference point(1 rotation signal) in spindle phase
synchronization.
4810
Permissible error pulses in spindle phase synchronization
Data type : Byte
Data unit : Pulse
Data range : 0 to 255
Specify permissible error pulses in spindle phase synchronization between
master and slave spindles.
NOTE) This is for outputting spindle phase synchronization completion signals
FSPPH1 to FSPPH4<F289.0 to F289.3>.
These signals will turn “1” when difference of error pulses between
master and slave spindles becomes lower than the specified value.
4811
Permissible error pulses in spindle synchronization
Data type : Word
Data unit : Pulse
Data range : 0 to 32767
Specify permissible error pulses in spindle synchronization between master
and slave.
NOTE) This is for outputting synchronous error monitoring signals SYCAL1 to
SYCAL4<F043.0 to F043.3>.
These signals will turn “1” when the synchronous errors(absolute value)
between master and slave spindles exceed the specified value.