4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 92 -
1741
Feedrate for assuming the termination of automatic corner deceleration
(for acceleration/deceleration after interpolation)
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Increment system Unit of data
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
Set the feedrate for assuming the termination of deceleration in
automatic corner deceleration.
1762
Exponential acceleration/deceleration time constant for cutting feed in the
advanced preview control mode
[Data type] Word axis
[Unit of data] ms
[Valid data range] 0 to 4000
Set an exponential acceleration/deceleration time constant for cutting
feed in the advanced preview control mode.
1763
Minimum speed in exponential acceleration/deceleration for cutting feed in
the advanced preview control mode
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Increment system Unit of data
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
Set minimum speed (FL) in exponential acceleration/deceleration for
cutting feed in the advanced preview control mode.