B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 149 -
#7 #6 #5 #4 #3 #2 #1 #0
3109 RHD IKY DWT
[Data type] Bit
DWT Characters G and W in the display of tool wear/geometry
compensation amount
0 : The characters are displayed at the left of each number.
1 : The characters are not displayed.
IKY On the tool offset screen and workpiece shift screen (T series), soft
key [INPUT] is:
0 : Displayed.
1 : Not displayed.
RHD When a manual handle interrupt is generated, the relative position
display is:
0 : Not updated.
1 : Updated.
NOTE
This parameter is enabled when the INH parameter
(bit 2 of parameter No.7100) is 1.
#7 #6 #5 #4 #3 #2 #1 #0
AHC OFA
3110
AHC
[Data type] Bit
OFA The axis names on the offset screen, Y-axis offset screen, and 4th axis
offset screen are:
0 : Always X, Z, and Y.
1 : As specified by parameter No. 1020.
AHC With a soft key, the alarm history:
0: Can be cleared.
1: Cannot be cleared.
#7 #6 #5 #4 #3 #2 #1 #0
3111 NPA OPS OPM SVP SPS SVS
[Data type] Bit
SVS Servo tuning screen
0 : Not displayed
1 : Displayed
SPS Spindle tuning screen
0 : Not displayed
1 : Displayed
SVP Synchronization errors displayed on the spindle tuning screen
0 : Instantaneous values are displayed.
1 : Peak-hold values are displayed.
OPM Operating monitor
0 : Not displayed
1 : Displayed
OPS The speedometer on the operating monitor screen indicates: