4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 162 -
NOTE
If the MER parameter (bit 6 of parameter No.3203)
is 1, executing the last block provides a choice of
whether to automatically erase a created program.
#7 #6 #5 #4 #3 #2 #1 #0
3205 MCK BGC OSC PNS CMO CHG COL
[Data type] Bit
COL When a program is displayed or output, any colons (:) in the
comments of the program are:
0 : Converted to letter O
1 : Displayed or output as is
CHG When the change function of the extended edit function is used:
0 : Once the user has decided whether to make a change, the cursor
is moved to the target position.
1 : The cursor is moved to the change source, after which the user
can choose whether to make a change.
CMO In extended tape editing, the copy or move operation:
0 : Is performed in the usual way.
1 : Can also copy or move data from a program to a key-in buffer in
units of words.
PNS On the program screen, a search by a cursor key is:
0 : Performed.
1 : Not performed.
OSC On the offset screen, offset value erasure by a soft key is:
0 : Enabled.
1 : Disabled.
BGC When background editing starts:
0 : The edit program is initialized (no program is selected).
1 : The previous edit program is edited continuously.
(Continuous editing is allowed only when neither editing nor
operation is being performed in the foreground (that is, when
continuation is possible).)
MCK The system tape memory check function is:
0 : Not used.
1 : Used. (This setting is inhibited.)
#7 #6 #5 #4 #3 #2 #1 #0
3206 NS2 PHS MIF
[Data type] Bit
MIF Editing of the maintenance information screen is:
0 : Not prohibited.
1 : Prohibited.
PHS The selection of an operation history signal and parameters (No.
12801 to No. 128900) are:
0 : Not linked.
1 : Linked.
NS2 The CNC screen display function dual display is:
0 : Not used.