B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 167 -
NOTE
The functions of the signals depend on whether
KEY=0 or KEY=1.
When KEY = 0:
- KEY1: Enables a tool offset value and a
workpiece zero point offset value to be
input.
- KEY2: Enables setting data and macro variables
to be input.
- KEY3: Enables program registration and editing.
- KEY4: Enables PMC data (counter and data
table) to be input.
When KEY = 1:
- KEY1: Enables program registration and editing,
and enables PMC parameter input.
- KEY2 to KEY4: Not used
#7 #6 #5 #4 #3 #2 #1 #0
3291 WPT
[Data type] Bit
WPT The input of the tool wear compensation amount is:
0 : Enabled according to memory protection key signal KEY1.
1 : Always enabled.
#7 #6 #5 #4 #3 #2 #1 #0
3292 PK5
[Data type] Bit
PK5 The KEYPRM signal (memory protection signal, parameter write
setting) is:
0 : Disabled.
1 : Enabled.
If this parameter is set to 1, PWE on the setting screen becomes
invalid, and the KEYPRM signal <G046#0> is used to make memory
protection and parameter write settings.