B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 171 -
NOTE
1 When 1 is set, specifying two or more G codes of
the same group in a block will also result in an
alarm being issued.
2 Up to three M codes can be specified in a single
block, when bit 7 (M3B) of parameter No.3404 is
set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
M3B EOR M02 M30 SBP POL
3404
M3B EOR M02 M30 SBP POL NOP
[Data type] Bit
NOP When a program is executed, a block consisting of an O number, EOB,
or N number is:
0 : Not ignored, but regarded as being one block.
1 : Ignored.
POL For a command address allowing a decimal point, omission of the
decimal point is:
0 : Enabled
1 : Disabled (P/S alarm No.5073)
SBP Address P of the block including M198 in the subprogram call
function
0 : Indicating a file number
1 : Indicating a program number
M30 When M30 is specified in a memory operation:
0 : M30 is sent to the machine, and the head of the program is
automatically searched for. So, when the ready signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1 : M30 is sent to the machine, but the head of the program is not
searched for. (The head of the program is searched for by the
reset and rewind signal.)
M02 When M02 is specified in memory operation
0 : M02 is sent to the machine, and the head of the program is
automatically searched for. So, when the end signal FIN is
returned and a reset or reset and rewind operation is not
performed, the program is executed, starting from the beginning.
1 : M02 is sent to the machine, but the head of the program is not
searched for.
EOR When the end-of-record mark (%) is read during program execution:
0 : P/S alarm No.5010 occurs. (Automatic operation is stopped, and
the system enters the alarm state.)
1 : No alarm occurs. (Automatic operation is stopped, and the
system is reset.)
M3B The number of M codes that can be specified in one block
0 : One
1 : Up to three
#7 #6 #5 #4 #3 #2 #1 #0
3405 QAB QLG DDP CCR G36 PPS DWL AUX