4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 176 -
#7 #6 #5 #4 #3 #2 #1 #0
3451
NBN CCK SDP GQS
[Data type] Bit
GQS When G33 is specified, the threading start angle shift function (Q) is:
0 : Disabled.
1 : Enabled.
SDP The function to specify an S command with decimal point is:
0 : Not used.
1 : Used.
An S command with one decimal place can be specified. However, the
S command value is rounded off to the nearest whole number.
Example:
Relationships between specified value and S code output/alarm
S200.5 -> S code output value = 201
S200.2 -> S code output value = 200
S200.12 -> P/S007 alarm is raised.
CCK If chamfering or corner R is enabled and if the end point specified in
an arc command is not complete,
0 : No alarm is raised.
1 : An alarm (P/S058 alarm) is raised.
This parameter specifies whether an alarm is raised if chamfering or
corner R is enabled, if the end point specified in an arc command is
not complete, and if an address is omitted.
If the end point is omitted in an arc command, chamfering or corner R
may affect the omitted point, and the operation may not be performed
as intended by the programmer. If this parameter is specified, an alarm
can be raised for that type of program execution.
NBN If bit 0 (NOP) of parameter No. 3404 is set to 1, a block including just
N (sequence number) is:
0 : Ignored.
1 : Not ignored but handled as a single block.
#7 #6 #5 #4 #3 #2 #1 #0
CRD
3453
[Data type] Bit
CRD If the functions of chamfering or corner R and direct drawing
dimension programming are both enabled,
0 : Chamfering or corner R is enabled.
1 : Direct drawing dimension programming is enabled.
If the functions of chamfering or corner R and direct drawing
dimension programming are both specified, this parameter specifies
which function is used.
This parameter is displayed also on the setting screen.
("CHAMFERING/DIRECT DRAWING DIMENSION
PROGRAMMING") The function to be enabled can be changed
from the setting screen or parameter screen.