B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 185 -
3627
Pitch error compensation (absolute value) at reference position when a
movement to the reference position is made from the direction opposite to
the direction of reference position return
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] -32768 to 32767
Set the absolute value of pitch error compensation at reference
position when a movement to the reference position is made from the
negative direction if the direction of reference position return (bit 5
(ZMI) of parameter No. 1006) is positive or from the positive
direction if the direction of reference position return is negative.