4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 188 -
#7 #6 #5 #4 #3 #2 #1 #0
3702 OR2 OR1
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
OR1 Whether the stop-position external-setting type orientation function is
used by the first spindle motor
0 : Not used
1 : Used
OR2 Whether the stop-position external-setting type orientation function is
used by the second spindle motor
0 : Not used
1 : Used
#7 #6 #5 #4 #3 #2 #1 #0
MPP
3703
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
MPP Under multi-spindle control, the spindle is not selected by a spindle
signal (SWS1 to SWS3 <G027 bits 0 to 2>), and a programmed
command (address P) is:
0 : Not used.
1 : Used.
NOTE
If this parameter is set to 1, set parameters No.
3781 to No. 3783 as well.