B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 231 -
Set the maximum allowable value for the tool wear compensation
value, input as an incremental value. If the incremental input value
(absolute value) exceeds the set value, the following alarm or warning
message is output:
Input from MDI
Warning: Setting value out of range.
Input using G10
P/S alarm No.032: Offset value is out of range by G10.
Distance (XP) between reference position and X axis + contact surface
Distance (X1P) between reference position and X axis + contact surface of
touch sensor 1
5015
Distance (XM) between reference position and X axis - contact surface
Distance (X1M) between reference position and X axis - contact surface of
touch sensor 1
5016
Distance (ZP) between reference position and Z axis + contact surface
Distance (Z1P) between reference position and Z axis + contact surface of
touch sensor 1
5017
Distance (ZM) between reference position and Z axis - contact surface
Distance (Z1M) between reference position and Z axis - contact surface of
touch sensor 1
5018
[Data type] 2-word
[Unit of data]
Input increment IS-B IS-C Unit
Millimeter input 0.001 0.0001 mm
Inch input 0.0001 0.00001 inch
[Valid data range] -99999999 to 99999999
These parameters are related to the function of input of tool offset
value measured B.
They set the distance (with sign) between the measurement reference
position and sensor contact surface. For an axis under diameter
programming, set it by a diameter value.