B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 257 -
Parameter No.5200#5 PCP=1
(Clearance in peck tapping cycle)
Parameter No.5200#5 PCP=0
(Return in peck tapping cycle)
q : Depth of cut
d : Return value
R point
Z point
q
q
q
d
d
q : Depth of cut
d : Clearance value
R point
Z point
q
q
q
d
d
Fig.4.23 (a) High-speed Peck Drilling and Peck Drilling Cycles
5214 Setting of an allowable rigid tapping synchronization error range
Setting of an allowable rigid tapping synchronization error range for the
second spindle
5215
[Data type] Word
[Unit of data] Detection unit (1/4096rev)
[Valid data range] 0 to 32767
Each of these parameters is used to set an allowable synchronization
error range between a spindle used for rigid tapping and the tapping
axis.
If the value set with each parameter is exceeded, rigid tapping alarm
No.741 (excessive error during movement) is issued. When 0 is set, a
synchronization error check is not made.
NOTE
When rigid tapping is performed using the second
spindle
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 0, the setting of parameter
No.5214 is applied to the second spindle, as
well as to the first spindle.
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 1, the settings of parameter
No.5215 is applied to the second spindle.