4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 268 -
NOTE
When rigid tapping is performed using the second
spindle
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 0, the setting of parameter
No.5312 is applied to the second spindle, as
well as to the first spindle.
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 1, the setting of parameter
No.5352 is applied to the second spindle,
respectively.
5313
Positional deviation limit imposed while the spindle is stopped in rigid
tapping
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed
while the spindle is stopped in rigid tapping.
NOTE
When rigid tapping is performed using the second
spindle
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 0, the setting of parameter
No.5313 is applied to the second spindle, as
well as to the first spindle.
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 1, the setting of parameter
No.5353 is applied to the second spindle,
respectively.
5314
Positional deviation limit imposed during tapping axis movement in rigid
tapping
[Data type] 2-word
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Usually, parameter No.5310 is used to set a positional deviation limit
imposed during tapping axis movement in rigid tapping. However,
parameter No.5314 can be used to set a value greater than the valid
data range of parameter No.5310 because of the resolution of the
detector being used.