B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 281 -
4.27 PARAMETERS OF NORMAL DIRECTION CONTROL
5480
Number of the axis for controlling the normal direction
[Data type] Byte
[Valid data range] 1 to the maximum control axis number
This parameter sets the control axis number of the axis for controlling
the normal direction.
5481
Rotation feedrate of normal direction control axis
[Data type] Word
[Unit of data] deg/min
[Valid data range] 1 to 15000
This parameter sets the feedrate of a normal direction control axis that
is inserted at the start point of a block during normal direction control.
5482
Limit value that ignores the rotation insertion of normal direction control
axis
[Data type] 2-word
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 1 to 99999999
The rotation block of a normal direction control axis is not inserted
when the rotation insertion angle calculated during normal direction
control does not exceed this setting value. The ignored rotation angle
is added to the next rotation insertion angle. The block insertion is
then judged.
NOTE
1 No rotation block is inserted when 360 or more
degrees are set.
2 If 180 or more degrees are set, a rotation block is
inserted only when the circular interpolation is 180
or more degrees.