4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 18 -
ASI Code used at data input
0 : EIA or ISO code (input: determined automatically, output:
setting of bit 1 of parameter No. 0000)
1 : ASCII code for both input and output
NOTE
When ASCII code is to be used for inputting and
outputting data (when ASI is set to 1), also set bit 1
of parameter No. 0000 to 1.
NFD Feed before and after the data at data output
0 : Output
1 : Not output
NOTE
When input/output devices other than the FANUC
PPR are used, set NFD to 1.
0102
Number specified for the input/output device (when the I/O CHANNEL is set
to 0)
[Data type] Byte
Set the number specified for the input/output device used when the
I/O CHANNEL is set to 0, with one of the set values listed in Table
4.2.2 (a).
Table 4.2.2 (a) Set value and Input/Output Device
Set value Input/output device
0 RS-232-C (Used control codes DC1 to DC4)
1
FANUC CASSETTE ADAPTOR 1 (FANUC CASSETTE B1/
B2)
2 FANUC CASSETTE ADAPTOR 3 (FANUC CASSETTE F1)
3
FANUC PROGRAM FILE Mate, FANUC FA Card Adaptor
FANUC FLOPPY CASSETTE ADAPTOR, FANUC Handy File
FANUC SYSTEM P-MODEL H
4 RS-232-C (Not used control codes DC1 to DC4)
5 Portable tape reader
6
FANUC PPR
FANUC SYSTEM P-MODEL G, FANUC SYSTEM P-MODEL H